石油学报 ›› 1985, Vol. 6 ›› Issue (2): 117-120.DOI: 10.7623/syxb198502014

• 论文 • 上一篇    下一篇

输气管线压气站站距计算

刘良治   

  1. 四川石油管理局勘察规划设计院
  • 收稿日期:1984-03-01 出版日期:1985-04-25 发布日期:2013-07-08

CALCULATION OF DISTANCE BETWEEN COMPRESSOR STATIONS ON GAS TRANSMISSION PIPELINES

Liu Liangzhi   

  1. Oil and Gas Surreying, Planning and Designing Institute of the Southwest Branch of China Petroleum Corporation
  • Received:1984-03-01 Online:1985-04-25 Published:2013-07-08

摘要: 本文论述输气管线压气站站距的计算方法。以输气量公式为依据,推导出全线等量输送、非等量输送情况下的站距公式。适用于布置压气站的计算。

关键词: 压气站, 输气管线, 输气量, 站距, 计算长度, 公式计算, 压比, 当量长度, 压缩系数, 输送

Abstract: Calculation of distance between gas compressor stations on gas transmission pipelines is discussed. Based on the equation of gas transmisson capacity, the distance equation used for various pipeline sections between two gas compressor stations under equivalent and inequivalent flow conditions is derived. This method of calculation is applicable in planning the distribution of compressor stations.